NPD, NEW INSTALLATION 2011


1 SUMMARY


Sensor:

Digitizer:

2 TEST OF SEISMOMETER


  • Model: Trillium 120PA
  • Mfr: Nanometrics
  • S/N: 1136

2.1 Factory configuration information


Commands entered are highlighted.

   tx
   Serial Transmit enabled.
   checksum
   Program A CheckSum: 0xe9f7, Original: 0xe9f7
   Program B CheckSum: 0x1c3f, Original: 0x1c3f
   getinfo
   Trillium120
   BIN 16214
   BOM 08
   ASY 01
   SN  1136

   FBE
   BIN ASM16136
   BOM 02
   ASY 02
   SN  0906

   ExtFlex
   BIN CCA14933
   BOM 05
   ASY 05
   SN  1102

   AxisU
   BIN ASM16210
   BOM 03
   ASY 03
   SN  3343

   FlexU
   BIN ASM16219
   BOM 02
   ASY 02
   SN  2065

   AxisV
   BIN ASM16210
   BOM 03
   ASY 03
   SN  3344

   FlexV
   BIN ASM16219
   BOM 02
   ASY 02
   SN  2068

   AxisW
   BIN ASM16210
   BOM 03
   ASY 03
   SN  3346

   FlexW
   BIN ASM16219
   BOM 02
   ASY 02
   SN  2315

2.2 Mass centering


Commands entered are highlighted.

   tx
   Serial Transmit enabled.
   soh
   <SOH>
   <Manufacture>"Nanometrics, Inc."</Manufacture>
   <Product>"Trillium Firmware"</Product>
   <Version>3.33</Version>
   <Temperature>29.33</Temperature>
   <Mass>U=0.537 V=-2.941 W=2.855</Mass>
   <Adc>U=243 V=-1329 W=1291</Adc>
   <Modes>Period=Long Channel=XYZ</Modes>
   <Positions>U=995 V=-684 W=730</Positions>
   <Level>U=700 V=-290 W=90</Level>
   <Range>U=+/-7144 V=+/-7154 W=+/-7206</Range>
   </SOH>
   center
   move=0, steps=0, per=3, pos=0, ADC=260
   move=1, steps=-412, per=3, total steps=-412, ADC=-18
   MC=CENTERED, Ch=U, Pos=583, Mass=-0.041V, ADC=-18
   move=0, steps=0, per=3, pos=0, ADC=-1261
   move=1, steps=890, per=3, total steps=890, ADC=1
   MC=CENTERED, Ch=V, Pos=206, Mass=0.001V, ADC=1
   move=0, steps=0, per=3, pos=0, ADC=980
   move=1, steps=-452, per=3, total steps=-452, ADC=10
   MC=CENTERED, Ch=W, Pos=278, Mass=0.021V, ADC=10
   soh
   <SOH>
   <Manufacture>"Nanometrics, Inc."</Manufacture>
   <Product>"Trillium Firmware"</Product>
   <Version>3.33</Version>
   <Temperature>29.30</Temperature>
   <Mass>U=-0.034 V=0.010 W=-0.012</Mass>
   <Adc>U=-15 V=5 W=-5</Adc>
   <Modes>Period=Long Channel=XYZ</Modes>
   <Positions>U=583 V=206 W=278</Positions>
   <Level>U=700 V=-290 W=90</Level>
   <Range>U=+/-7144 V=+/-7154 W=+/-7206</Range>
   </SOH>